The main advantage of the NFT system over other forms of hydroponics – bag, media and soil culture – is that the plant roots are exposed to adequate supplies of water, oxygen and nutrients. In all other forms of production there is a conflict between the supply of these requirements, since excessive or deficient amounts of one results in an imbalance of one or both of the others. NFT, because of its design, provides a system where all three requirements can be met at the same time, providing the simple concept of NFT is always remembered and practised. The result of these advantages is that higher yields of high quality produce are obtained over an extended period of cropping.
Flooding and waterlogging of roots, or other problems due to poor design, construction or operation may occur with resulting crop loss. These problems result from producers forgetting the simple concepts of NFT production systems, and constitute the main disadvantages found in the operation of the NFT system. Other disadvantages are associated with the dependence of NFT on reliable supplies of water and power. If breakdowns occur, and suitable back-ups have not been provided, more serious losses can result than in media systems where a degree of buffering is present.
Gully Gullies for long term crops with large root systems have been devised using metal, fibreglass, plastic and polystyrene trays, some of which are lined with a plastic film. A wide range of materials have been encountered and include purpose-made plastic gullies. The most practical and cheapest commercial method, at present, requires a level floor or firm support base, upon which folded black and white 800mm wide PVC plastic film is laid, so that the flat base is at least 200m wide and the two equal sides are folded and supported across the top to form an inverted ‘ T ‘.
As a general guide, flow rates for each gully should be 1 litre per minute. At planting, rates may be half this and the upper limit of 2L/min appears about the maximum. Flow rates beyond these extremes are often associated with nutritional problems.
Depressed growth rates of many crops have been observed when gullies exceed 12 metres in length. On rapidly growing crops, tests have indicated that, while oxygen levels remain adequate, nitrogen may be depleted over the length of the gully. Consequently, gully length should not exceed 10-15 metres. In situations where this is not possible, the reductions in growth can be eliminated by placing another nutrient feed half way along the gully and reducing flow rates to 1L/min, through each outlet.
Pipes from the pump to the manifolds supplying the gullies, are generally ridged PVC pressure water pipes used in domestic houses. They should be installed to avoid air locks and may be protected from the heat of the sun and insulated if outside the house. Since the solvents in many glues are toxic to plants, allow adequate flushing after gluing, especially when temperatures are below 20°C. Do not plant up until the taste of the glue solvents cannot be detected. Pipe sizes should allow for laminar flow rates within any house or system of manifolds, so that the system is balanced and indivdual manifolds do not vary in their delivery pressures. Ring mains may be used to achieve this on larger establishments. Flow rates and head losses should be determined for each section of the unit.
The nutrient is frequently discharged into a manifold from which narrow tubes of 3-4mm carry it into the gullies. Flow control taps may be placed at the entry of the pressure lines to the manifolds, but can usually be avoided by having a balanced system and a single flow control tap on the pump bypass.
A weak link in many systems is the method used for collection of solution from the gullies for return to the catchment tank. The collection points must be designed so that dirt, dust or water from the house, surface flooding or leaks cannot enter the system. The most satisfactory design is to provide open concreted channels, which are sloped for waste water drainage. The gully drains may be placed in these, raised from the bottom and away from the sides. The size of the collector pipes should be 80mm or more and designed to take the normal flow from the gullies, using open channel flow rates for the fall available, and of sufficient size so that they are never more than 50% full. Once free from the gullies, a dropper of 300mm can be provided and from that point a drain capable of carrying flows calculated for normal pipes can be used.
Tanks may be constructed of non-toxic plastics, fibreglass or stainless steel. Other unsuitable structures may be lined with plastic. Food grade materials should be used. In most systems the nutrients drain into a catchment tank of a capacity (measured in litres) at least 1 to 4 times the effective crop area of the system (measured in sq. metres). Tanks should be protected with covers and may be housed, with control equipment, in a small shed. The catchment tank should be set in a pit and, unless sub-soil drainage is free, provided with an automatic pump to keep the water table low. If drainage is not adequate, during wet conditions the tank is likely to float out of its hole, damaging connections.
‘A’ and ‘B’ nutrients are held in two 100L or 200L plastic drums. These discharge through solenoids directly into the catchment tank. Flow rates must be equal and are adjustable either by cutting the discharge microtube or with suitable taps. pH adjustment may be by air displacement of the acid or alkali, or a small pump or solenoid may be used.
A range of controllers is available for automatic dosing and control of pH. Some work on 12 volt solenoids, while others use 240 volt systems. When purchasing the solenoids, ensure that the correct wattage and voltage for AC or DC are obtained. Control of units exceeding the rating of the control equipment is possible through a relay.
Nutrient from the A and B tanks is added in equal amounts to the catchment tank, to maintain the correct concentration measured by conductivity. Water enters the tank to replace that lost by transpiration. pH is monitored and corrected, normally by the addition of acid, so the system operates close to pH 6.3. The solution in the catchment tank is circulated through the NFT system and returns, dropping some distance into the tank to assist aeration. The solution is dumped and replaced as unwanted ions, such as sodium, reach unacceptable levels.
Plant vigour and root health is enhanced if the solution is heated to 18°C. The temperatures of the solution should normally be run between 15°C and 24°C. Stainless steel electric immersion heaters or heat exchange units may be used.
While few growers use alarms, the following are systems where it is desirable to have alarms or safeguards fitted.
2. Conductivity and pH: Provide alarms to warn when acceptable tolerances (say 10%) are exceeded.
3. Leaks: Install a pressure switch (normally on at mains pressure, open when water is entering the system) close to the float valve outlet. A flow restrictor may be required on the mains side of the pressure switch. Wire this pressure switch in series with dosing solenoids so that, if water is continually entering the system, dosing will not occur. No separate alarm is required. Conductivity is lowered and that alarm is triggered.
4. Temperature Control and Heating: Install thermostats to warn of solution and house temperatures above and below requirements.
5. Pump Pressure: Install a pressure switch near the pump to warn of pump failure or large leaks in the pressure system.
6. Power Failures: Install a warning device so that early attention can be provided.
NFT is a hydroponics system that is well established for commercial and domestic short and long term crops, and high yields of quality produce are readily produced by this method. Frequently, problems are encountered when the basic principles of the system’s operation are neglected. These principles are described at the start of this article and it is wise to review them frequently and ensure that the requirements are being achieved requirements are being achieved.